معلومات المنتج
ECG300G Human Use Machine (With Software) Introduction ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management. Function 1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal. 2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing. 3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements. 4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden. 5)Built-in memory stores up to 1000 cases, convenient for case review and statistic. 6)Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report. Performance Input mode: floating and defibrillation protection Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB) CMRR: >60dB, >100dB(add filter) Time constant:≥ 3.2s Patient leak current: <10µA Calibration voltage: 1mV Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2% Noise level: <15µVp-p Input circuit current: ≤50nA Input impedance: ≥50MΩ Sampling accuracy: 12-bit Safety classification: class I, type CF and defibrillation-proof applied part Recording mode: thermal printing system Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing. Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing. Manual record: set record according to record format, manually switching leads. Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) Paper size: 80mm(W)×20m(L) Sampling frequency: 1000Hz EMG interference filter: 25Hz/35Hz (-3dB) Power frequency filter: AC 50Hz/60Hz(-20dB) Paper speed: Auto: 25, 50mm/s, ±5% Rhythm: 25, 50mm/s, ±5% Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5% Accessories Standard: A lead cable A limb electrode A chest electrode A thermal recording paper A power cord An earth wire A user manual ECG-Sync software+USB cable Physical characteristic Power supply: AC: 100V~240V(50/60Hz) DC: 7.4V/3500mAh rechargeable lithium battery Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V Waterproof degree: IPX0 Working mode: continuous working ECG300G Veterinary Use Machine (Software Not Include) Introduction ECG300G-VET is an Electrocardiograph which can collect 12-lead ECG signal simultaneously and print waveform by thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, optional rhythm lead that convenient to observe abnormal heart rhythm, case database management, etc. Function 1)Sync collection, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal. 2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing. 3)Multiply printing modes and formats, including manual, auto 4x3, auto 3x4+1, auto 3x4, auto 2x6+1, auto 2x6, auto 3-2+1, auto 3-2, auto 1x12+1, auto 1x12, rhythm 4, rhythm 3, rhythm 2, etc. Waveform length printed can be adjusted, and with timed print function, which meets different requirements. 4)Build-in large capacity memory stores at least to 1000 cases, which is convenient for doctor to review case and statistic. 5)Multi- language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Russian, Ukrainian, Serbian, Vietnamese, Slovenian, Slovak, Bulgarian and Nigerian language) interface and report. Performance Input mode: floating and defibrillation protectionLead: 7-lead Patient leakage current: <10 µA Input impedance: ≥2.5MΩ Frequency response: Rated input amplitude Input frequency and waveform Relative output response 1.0 0.67Hz~40Hz, Sine wave ±10%a 0.5 40Hz~100Hz, Sine wave +10 %, -30 %a 0.25 100Hz~150Hz, Sine wave +10 %, -30 %a 0.5 150 Hz ~ 500 Hz, Sine wave +10 %, -100 %a 1.5 ≤1Hz,200ms, Triangle wave +0 %, -10 %b a relative to 10Hz b relative to 200 ms Time constant:≥ 3.2s CMRR: >105dB Filter: power frequency(AC50/60 Hz), EMG(25 Hz/35 Hz (-3 dB)), baseline drift filter Recording way: thermal printing system Specification of recording paper: 80 mm(W)×20 m(L) high-speed thermal paper Time base selection(paper speed): 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5% Gain control(sensitivity): 5, 10, 20 mm/mV, accuracy is ±2%; Standard sensitivity: 10 mm/mV±0.2 mm/mV Recording mode: auto mode, rhythm mode and manual mode Safety classification: Class I, type CF defibrillation-proof applied part Polarization resistance voltage: ±610mV Noise level: ≤12 µVp-p ECG signal input sampling frequency: 32 kHz Waveform data processing sampling frequency: 1 kHz Sampling accuracy: 24-bit The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected Pacing detection channel: standard II Accuracy of input signal: ±5% Amplitude quantization: ≤5µV/LSB Dimension: 315 mm(L)×215 mm(W)×77 mm(H) Weight: 1.6 kg Interchannel time deviation: <100 µs Power supply: AC: 100V~240V(50/60Hz) DC: 7.4V/3500mAh rechargeable lithium battery Degree of protection against ingress of liquid: IPX0 Working mode: continuous working Accessories A lead cable A limb electrode A thermal recording paper A power cord An earth wire A user manual Physical characteristic Working environment Temperature: 5℃~40℃ Relative humidity: 25%~95%(non-condensing) Atmospheric pressure: 700 hPa~1060 hPa Transport and storage environment Temperature: -20 ℃~+55 ℃ Relative humidity: ≤95% Atmospheric pressure: 500 hPa~1060 hPa Dimension: 315mm(L)×215mm(W)×77mm(H) Weight: 1.6Kg
مواصفات المنتج
جهاز تخطيط القلب الرقمي Contec ECG300G بـ 3 قنوات و12 طرفًا
- رضا المشترين ٨٠٪
🚚 يصلك تقريباً بين 1 نوفمبر و14 نوفمبر
حماية المشتري: إن وصلتك القطعة تالفةً أو مختلفةً عن الوصف أو لم تصل، نعيد لك المبلغ كاملاً. بلّغنا خلال ١٤ يوماً من الاستلام مع صورة.
الدفع عند الاستلام (نقداً)
بيميرا
بطاقة فيزا أو ماستركارد
شام كاش
بنك الشام













