معلومات المنتج
CONTEC Modular Patient Monitor 13‘’Big Display Touch Screen Plug-In Monitor ECG NIBP SPO2 Resp Temp 2-IBP&Sidetream Etco2 Function 1)13.3" high-definition touch screen design, easy and convenient to operate, elegant and concise in appearance. 2)Independent physiological and technical alarm function, convenient for medical staff to quickly know patient’s condition. 3)Luminous “ON / OFF” button design, convenient to operate at night. 4)Modular design: the modules can be configured and combined flexibly and conveniently, expanded and upgraded at any time, meets the monitoring requirements of different departments on different parameters. 5)Support dynamic hot-plugging parameter module: no need to restart the device, plug-and-play, change the monitoring parameters at any time as clinical requirements. 6)Adopt high-performance processor, stable, reliable and fast to process information. 7)Patient information can be rapidly entered, patient type (adult / neonate / pediatric) can be quickly switched, meets the requirements of different departments. 8)Abundant analysis functions: 23 arrhythmia, full-lead ST-segment and pacing analysis; multiple calculation functions (such as calculation of drug concentration, titration table, hemodynamics, ventilation, oxygenation, renal function, etc.). 9)With the functions of waveform freezing, holographic waveform storage and review. 10)Automatic data storage in case of power failure; optional built-in memory card, achieves large-capacity data storage. Performance (1)ECG Lead type: 3-lead: I, II, III 5-lead: I, II, III, aVR, aVL, aVF, V 12-lead: I, II, III, aVR, aVL, aVF, V1,V2,V3,V4,V5,V6 Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV Scan speed: 12.5 mm/s, 25 mm/s, 50 mm/s HR Measurement and alarm range: Adult: 15 ~ 300 bpm Pediatric/neonate: 15 ~ 350 bpm Resolution: 1 bpm Accuracy: ± 1 % or ± 1 bpm, whichever is greater ST-segment detection Measurement and alarm range: - 2.0 mV ~ + 2.0 mV Accuracy: - 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater Arrhythmia analysis: 23 kinds Pacemaker: yes (2)RESP Measurement mode: R-F (RA-LL) impedance Adult: 0 rpm ~ 120 rpm Pediatric/neonate: 0 rpm ~ 150 rpm Resolution: 1 rpm Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater; 0 ~ 6 rpm, unspecified Apnea alarm: 10 ~ 120 s, not alarm Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s (3)NIBP Measurement mode: Oscillometry Working mode: Manual/AUTO/Continuous Measurement interval in AUTO mode: 1 min, 2 min, 2.5 min, 3 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 1.5 h, 2 h, 3 h, 4 h, 8 h Measurement period in Continuous mode: 5 minutes Measurement and alarm range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ± 3 mmHg Measurement accuracy: Maximal mean deviation: ± 5 mmHg Maximal standard deviation: 8 mmHg Adult mode: 297 ± 3 mmHg Pediatric mode: 240 ± 3 mmHg Neonatal mode: 147 ± 3 mmHg (4)CONTEC SpO2 Measurement range: 0 % ~ 100 % Resolution: 1 % Accuracy: 70 % ~ 100 %, ± 2 %; 0 % ~ 69 %, unspecified PR Measurement and alarm range: 25 ~ 250 bpm Accuracy: ± 2 bpm or ± 2 %, whichever is greater (5)Nellcor SpO2 Measurement range: 1 % ~ 100 % Measurement accuracy: 70 % ~ 100 %: ± 2 % (adult / pediatric) 70 % ~ 100 %: ± 3 % (neonate) 0 % ~ 69 %: unspecified Nellcor PR Measurement range: 20 ~ 300 bpm; Measurement accuracy: 20 ~ 250 bpm, ±3 bpm; 251 ~ 300 bpm: unspecified; Upper limit of alarm: upper limit - 2 ~ 300 bpm; Lower limit of alarm: 20 bpm ~ lower limit + 2 bpm (6)Masimo SpO2 Measurement range: 1 % ~ 100 % Measurement accuracy: 70 % ~ 100 %: ± 2 % (adult / pediatric, under conditions of no motion), ± 3 % (under conditions of motion) 70 % ~ 100 %: ± 3 % (neonate, under conditions of no motion) 1 % ~ 69 %: unspecified Masimo PR Measurement range: 25 ~ 240 bpm Measurement accuracy: ± 3 bpm (under conditions of no motion), ± 5 bpm (under conditions of motion) Upper limit of alarm: upper limit - 2 ~ 240 bpm Lower limit of alarm: 25bpm ~ lower limit + 2 bpm (7)TEMP Channel: dual-channel Measurement range: 0 ~ 50 ℃ Resolution: 0.1 ℃ Accuracy: ± 0.1 ℃ (8)CO2 Measurement mode: mainstream or sidestream CO2 measurement range: 0 ~ 150 mmHg CO2 resolution: 0.1 mmHg: 0 ~ 69 mmHg 0.25 mmHg: 70 ~ 150 mmHg Accuracy: 0 ~ 40 mmHg: ± 2 mmHg 41 ~ 70 mmHg: ± 5 % 71 ~ 100 mmHg: ± 8 % 101 ~ 150 mmHg: ± 10 % AwRR measurement range: Sidestream: 2 ~ 120 rpm Mainstream: 2 ~ 150 rpm AwRR accuracy: ± 1 rpm Apnea alarm: yes (9)IBP Channel: 4-channel Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and alarm range: -50 ~ 300 mmHg Resolution: 1 mmHg Accuracy: ± 2 % or 1 mmHg, whichever is greater (10)Power supply: 100 ~ 240 V ~ 50/60 Hz (11)Safety class: class I, defibrillation-proof type CF applied part (12)Waterproof degree: IPX2 Accessories 1)TS13 multi-parameter module 2)ECG cable: 5-lead, American standard, TPU 3)SpO2 probe (integrated) Digital fingertip SpO2 probe for adult (CMS-N-SPO2 6P, 3M, yellow) 2)TEMP probe :R25=2.252K TEMP probe, skin surface type, CMS-N-TEMP 2P, PVC, L=3M 5)NIBP cuff:BP extension tube, L=3M 6)Adult cuff (25 ~ 35 cm) 7)EtCO2 8)IBP
مواصفات المنتج
شاشة مراقبة المرضى التجميعية Contec بحجم 13.3 بوصة باللمس
🚚 يصلك تقريباً بين 11 نوفمبر و24 نوفمبر
حماية المشتري: إن وصلتك القطعة تالفةً أو مختلفةً عن الوصف أو لم تصل، نعيد لك المبلغ كاملاً. بلّغنا خلال ١٤ يوماً من الاستلام مع صورة.
الدفع عند الاستلام (نقداً)
شام كاش













