Product information
CMS6600B EMG/EP System Nerve Muscle Bioelectricity Evoked Potential (Computer is not included) Description Introduction: The equipment records bioelectricity activity of nerve muscle for determining its function state, which combines with nerve conduction speed, to give patient an auxiliary diagnosis. Checking contents: EMG(electromygram), MCS(motor nerve conductor velocity), SCS(sensory nerve conductor velocity), F wave, Hreflex, RNS(repetitive nerve stimulation), Blink Reflex, VEP(visual evoked potential), BAEP(brainstem auditory evoked potential), SEP(somatosensory evoked potential), etc. Features: ■ Professional EMG/EP operation platform and perfect test items, complete each test in the shortest time. ■ Neuro and muscle navigation system, convenient in selecting test part. ■ Powerful normal values system, contrast with normal data automatically. ■ Flexible software design, configure system parameters according to requirements. ■ High-speed data collection, electromagnetic interference suppression, Photoelectric isolation and low noise. ■ Integrative hardware system, compact in configuration and easy in moving. Performance: ■ Main system part A/D conversion resolution 16 Bit Sampling ratio 200kHz Analysis time 5-5000ms Stimulating frequency 0.1-50Hz ■ Amplifier part Four-channel Sensitivity 0.05μV-20mV/Grid Earth noise EMG <= 4μV(Vpp) EP <=0.1μV(Vpp) (1000 times in average) Common-mode rejection ratio >= 100dB 50Hz Ban wave setting: Upper limit for Filter-frequency 20kHz Lower limit for Filter-frequency 1Hz Gain amplifies 25 times-400000 times ■ Stimulator part Constant current 0.2-100mA Pulse width 50-1000μS Short circuit and overloading protection ■ Auditory Stimulator Stimulation wave 40Hz Short, Sound Stim Stimulation polarity nondense wave, dense wave and alternant wave. Sound strength 40-120db (5db per level) Stimulation mode left, right, left & right Frequency of 40Hz carrier wave 500-8000Hz ■ Visual stimulator Mode tessellation, horizontal bar and vertical bar. Stimulation view all-view, half-view and quarter-view Resolution 3x4, 6x8, 12x16, 24x32, 48x64 Flash stimulator all quench,left light,right light,l&r light Physical characteristic: Dimension 420mm*350mm*46mm(L×W×H) Net weight 6KG Accessories: ■ Disk ■ Power Cord ■ Power Adapter ■ USB Cable ■ Audio Cable ■ Earth Cable ■ Current Stimulator ■ One-off Bipolar Needle Electrode D039035408, 0.35*40mm, D039060706, 0.60*70mm ■ Reuseable Bipolar Needle Electrode R039035408, 0.35*40mm, R039060706, 0.60*70mm ■ Concentric Needle Connecting Wire ■ 1mm Connecting Lead Wire ■ Disc Electrode ■ Ring Electrode ■ Surface Electrode ■ Ground Electrode(Include lead cable) ■ One-off Unipolar Needle Electrode ■ From 1 to 2 Conversion Cable ■ Surface Electrode Conversion Cable ■ Fuse 0.1A/250V, 5*20mm ■ Fuse F1.6AL250V, 5*20mm ■ Flash Stimulator ■ Audio Stimulator
Product specifications
CONTEC CMS6600B EMG/EP System Machine for Nerve & Muscle Bioelectricity
🚚 Arrives approx. November 10 – November 23
Buyer protection: full refund if your item arrives damaged, not as described, or never arrives. Report it within 14 days of delivery with a photo.
Cash on delivery
Sham Cash

