Shipped to your doorFrom our warehouses in China, the Gulf and EuropeBuyer protectionFull refund within 7 daysClear pricingShipping and fees shown before you pay

Product information

NOT FOR SALE IN U.S. MARKET Introduction KT88 Digital Brain Electric Activity Mapping collects EEG signal with electrodes, via integrated amplification, A/D transformation, PC auto-analysis, FFT, to form electroencephalogram that displays with color depth. The product is applicable for checking such diseases as epilepsy, intracranial inflammation, cerebrovascular diseases and brain tumors. Features Method of 10/20 electrodes placement under international standard system, leads can be changed during replaying. Support different types of combined leads during sampling. Adopt bioelectricity amplifier for distilling brainwave, continuous recording time can be up to 24 hours, integrated full-automatic calibration system. Powerful playback function: amplitude and display speed are adjustable. The special subdividing time line divides the waveform in one second into 5 parts, which is easy for doctors to look over the waveform. Digital filter system can be set as required, providing different window types EEG signal clipping function, analyze and store any section of EEG wave, and select several waveform segments for automatically analyzing and distilling to different parameters. Electronic frequency ruler, convenient to measure the basic information of any appointed EEG waveform. With partial enlarging window, accurate measurement of EEG period, amplitude and frequency, which can be adjusted according to personnel judgment. Mark EEG wave under the events of opening eyes, closing eyes and flashing with different colors, and user-defined events can be added, waveform color for evoked event can also be set freely, ensures that the waveform in corresponding time can be rapidly found by event name during case playback. Powerful automatic analysis function, can carry through the power spectrum analysis and pathologic wave detection for appointed waveform. Many graphs can be displayed in the same screen, including kinds of BEAM, numerical BEAM, compressed spectrum graph, trend graph, and so on. Professional isolation transformer, dual power supply isolation system and optoelectronic data transmission to ensure security. Use USB interface to transmit data which just need to be inserted. Multifunctional flash stimulator of USB interface, and flashing can be controlled manually or automatically. A flash stimulation scheme can be set and performed in the process of sampling. Perfect case management function, provides many means for research and quick statistic information; convenient case export and import function, and stores with MO or CD-RW disk, which is easy for data research. Integrative image and character report, report can be edited in mode and switched to Word document. Case files can be transformed into EDF and BDF data format, convenient for data exchange, academic exchange and further analysis. System parameters and display modes can be set as required, which meets different user’s requirement. Add marks and annotations to the waveform designated, which can rapidly find the waveform in that time by marks. Optional video function: USB camera is easy to install, convenient to use and exact to record. With flexible playback function, which can browse the waveform of any time along with the corresponding isochronous sampled image. SpO2 function is optional. Performance 16 channels of EEG+2 channels of ECG (ECG is optional) Sampling rate: 100 dots/s Accuracy: 12bit Input impedance: ≥10MΩ Patient leak current: < 10µA Noise level: ≤5µVp-p CMRR: ≥90dB Magnification multiple: 10000 Filter constant: all digital and free enactment Display speed(paper speed): 5, 10, 15, 30, 60, 120 mm/s Amplitude: 1, 1.5, 2, 3, 5, 7.5, 10, 12, 15, 20, 30, 50 mm/50µV Playback speed:1 time, 2 times, 3 times, 10 times, 20 times, 40 times, 60 times 50Hz interference suppression: ≥30dB Safety type:Class II, type BF applied part Accessories Standard EEG lead EEG electrode Data line Headgear Strobe light Strobe light power supply User Manual Earth wire EEG bracket Aluminum block Physical characteristic Dimension: 186 mm(L)×135 mm(W)×89.2 mm(H) Weight: 550g Operational environment: Temperature: +5℃~+40℃ Relative humidity: ≤85% Atmospheric pressure: 700hPa~1060hPa Power supply: USB 5V DC Storage environment: Temperature:-20℃~+55℃ Relative humidity: ≤90% Atmospheric pressure: 700hPa~1060hPa Certification SFDA certificate and CMC certificate.

Product specifications

Origin🇨🇳 China
Weight5.8 kg
Materialبلاستيك
Dimensions42.2 × 34 × 40 cm
Package weight5.8 kg
Packagingكرتون

KT88-1016 16 Channel Digital EEG Brain Activity Mapping System

69,685 SYP · 497.75 $
Similar items available in SyriaLocal items in the same category: 31
Quantity:
1 Piece

🚚 Arrives approx. November 12 – November 25

Economy shipping starts at 0.5 m³ — your cart is 0.057 m³.

HighlightsSee all ›
Origin🇨🇳 China
Weight5.8 kg
Materialبلاستيك
Dimensions42.2 × 34 × 40 cm
Package weight5.8 kg
Packagingكرتون
Protected by Zanbbel · 7-day buyer protection

Buyer protection: full refund if your item arrives damaged, not as described, or never arrives. Report it within 14 days of delivery with a photo.

Pay with
  • Cash on deliveryCash on delivery
  • Sham CashSham Cash
Ask about this product on WhatsApp

Similar products