Kapınıza kadar kargoÇin, Körfez ve Avrupa depolarımızdan
Alıcı koruması7 gün içinde tam iade
Net fiyatKargo ve ücretler ödemeden önce görünür

12V 24V Normal Close NC NO Normal Open Diesel Engine Stop Solenoid Valve Flame Out Device Off Valve Generator Accessories

2.505 SYP · 17,89 $3.976 SYP−37%

اللون
الفولتيّة
1 Adet
Öne çıkan özelliklerTümünü gör ›
Menşe🇨🇳 الصين
Ağırlık0,5 kg
Boyutlar15 × 15 × 10 cm
Paket ağırlığı0,5 kg
Zanbbel güvencesi · 7 gün alıcı koruması

Buyer protection: full refund if your item arrives damaged, not as described, or never arrives. Report it within 7 days of delivery with a photo.

Ödeme
  • Cash on delivery
  • Sham Cash
  • Paymera — Syrian cardPaymera
  • Visa or Mastercard cardVisa or Mastercard card
  • Sham CashSham Cash
  • Bank Al-Sham — deposit or transferBank Al-Sham
Bu ürünü WhatsApp'tan sor

Ürün bilgileri

Normal Close NC 24V Engine Flame Out Device Off Valve XHQ-PT- NC One: technical parameter The purpose of working voltage: 12V (9-15V DC) 24V (18-30V DC) Purpose: 12V-2.0A 24V-1.0A (full of action current moves in place automatically disconnect the power supply, the working current of <15mA) In the line of control working current: <15mA Travel: 53 + 1mm. The maximum tension: 90N. An ambient temperature: -30 to 60 DEG C The action time: less than 2 seconds. An overload protection extinguisher: the load is too large or stuck, stop working automatically,avoid flameout device damage. Disconnect the power off after a period of time, re power,extinguisher from fault reset, can resume normal work. Two, flameout device wiring: The flameout device has 3 lead wires, as follows: Red: connect the positive power supply: the cathode of a power supply (yellow green or blue)as the line of control: Open type: control line power extinguisher action, action in place, automatic stop. The release of extinguisher power, action in place, automatic stop. Closed type: control line power extinguisher action, action in place, automatic stop.Release extinguisher power control line, automatic stop action in place. Three, installation and notice The installation and commissioning should ensure the extinguisher action in place before,diesel engine stop control rod no action to the limit position and the extinguisher stuck,otherwise the extinguisher internal overload protection circuit, automatic flameout device stops working, the extinguisher should disconnect the power, adjust the mounting position, back to the extinguisher on electricity, flameout which can resume normal work.

Ürün özellikleri

Menşe🇨🇳 الصين
Ağırlık0,5 kg
Boyutlar15 × 15 × 10 cm
Paket ağırlığı0,5 kg

Benzer ürünler